Printed pages leave this bar out.

Pyrotechnics store transaction record

01/10/2026 to 05/11/2026, produced 05/11/2026 at 22:28 from the register's records. Quantities are devices; NEQ is the net explosive quantity in grams from each device's data, and "not recorded" where the sheet does not give one.

Misfires this period, by category

Category (ABTT IGN 08a)Misfires
mechanical0
product0
crossfire0
human error0
Total0

No misfires were recorded at performances in the period. Failed devices go back into their original packaging and out by the manufacturer's disposal route, never general waste.

Pyro Cabinet

Opening: 40 devices, 89.6 g NEQ  ·  Closing: 40 devices, 89.6 g NEQ

Treated as HT4 for storage: 89.6 g (aggregation rule — a mixed store counts as its most energetic type). 7 devices take the hazard type from the UN division on the sheet (1.4 = HT4), as packaged for carriage — record the supplier's hazard type if it differs.

DateMovementWhatQuantity NEQ (g)BatchDetailDevices after NEQ after (g)
No movements in the period.

Regulation 36 of the Explosives Regulations 2014 requires records of the acquisition, use, transfer and disposal of explosives, kept for ten years. This report and the per-item traceability record are produced from the same append-only tables, so either can be produced again for any past period.