Gathered from every register on 2026-11-05 at 22:29:05. Everything
here is worked out from the records at this moment — the tabs will say the
same thing.
Failed pyrotechnics awaiting disposal
No misfires are waiting to be disposed of.
Access equipment
Overdue by 1688 days Tallescope · Aluminium Access Products 9812
Overdue by 747 days Ivy 034 · Ladder
Overdue by 747 days Ivy 035 · Ladder
Overdue by 386 days Ivy 001 · Ladder
Overdue by 386 days Ivy 011 · Step ladder
Overdue by 198 days Tallescope · Aluminium Access Products 50518
Overdue by 198 days Tallescope · Aluminium Access Products 50518
Overdue by 22 days MEWP — scissor lift · Genie GS1932
Overdue by 22 days MEWP — scissor lift · Skyjack SJ3226
Overdue by 15 days Ivy 001A · Ladder
Overdue by 15 days Ivy 002 · Step ladder
Overdue by 15 days Ivy 003 · Step ladder
Overdue by 15 days Ivy 004 · Step ladder
Overdue by 15 days Ivy 005 · Ladder
Overdue by 15 days Ivy 008 · Ladder
Overdue by 15 days Ivy 013 · Ladder
Overdue by 15 days Ivy 016 · Step ladder
Overdue by 15 days Ivy 017 · Step ladder
Overdue by 15 days Ivy 018 · Step ladder
Overdue by 15 days Ivy 019 · Step ladder
Overdue by 15 days Ivy 019a · Step ladder
Overdue by 15 days Ivy 024 · Ladder
Overdue by 15 days Ivy 025 · Step ladder
Overdue by 15 days Ivy 026 · Step ladder
Overdue by 15 days Ivy 026a · Step ladder
Overdue by 15 days Ivy 038 · Step ladder
Overdue by 15 days Ivy 039 · Step ladder
Overdue by 15 days IVY 040 · Step ladder
Overdue by 15 days Ivy 041 · Step ladder
Overdue by 15 days PATs 022 · Ladder
Overdue by 15 days PST 0026 · Ladder
Faults reported and not yet looked at
No kit in use has an open fault from a pre-use check or a QR report.
Kit reaching the end of its life
Nothing with a recorded lifespan is near its retirement date.
Advisories still standing
MEWP — scissor lift · Genie GS1932 — advisories from 2026-04-14: 2. All Batteries below Plate Level.
3. Reset Overload System, rectified on Inspection.
MEWP — scissor lift · Skyjack SJ3226 — advisories from 2026-04-14: 2. Cage Controller Emergency Stop loose, rectified on Inspection.
Tickets and training
Nothing expired or expiring in the next 90 days.
Items with no safety data sheet
Every item has a sheet behind it.
Shelf-life reviews due
No review-by dates have passed.
Sheets worth checking for a newer edition (over 5 years old)
Chalk Bottle — sheet dated 2010-07-29 (16.3 years old, from the revision date printed on the sheet)
Tensospray — sheet dated 2011-03-07 (15.7 years old, from the revision date printed on the sheet)
Beamz Super Density Smoke — sheet dated 2012-01-01 (14.8 years old, from the revision date printed on the sheet)
ICO 16g threaded CO2 Cartridges — sheet dated 2012-10-01 (14.1 years old, from the revision date printed on the sheet)
MSL Fire Check — sheet dated 2015-09-30 (11.1 years old, from the revision date printed on the sheet)
Le Mark Pal Cleaner with Pump Spray Applicator — sheet dated 2016-02-01 (10.8 years old, from the revision date printed on the sheet)
Swan Gas Lighter Refill — sheet dated 2016-04-01 (10.6 years old, from the revision date printed on the sheet)
Ronsonol Lighter Fluid — sheet dated 2018-01-19 (8.8 years old, from the revision date printed on the sheet)
Flints Blaza Block — sheet dated 2019-02-08 (7.7 years old, from the revision date printed on the sheet)
Helium Canister — sheet dated 2020-03-24 (6.6 years old, from the revision date printed on the sheet)
Classifications that disagree with PubChem's listing
No stored cross-check lists a pictogram the records lack.
Risk assessments resting on an older reading
Every kept assessment was generated from the record as it stands.
41 item(s) have no CAS number and could not be screened.
Stock that does not add up
No holding is below zero.
Productions promising more than is held
Every scheduled firing is covered by the devices held.
Chemicals below their minimum
Nothing with a minimum set is below it.
Batches at or past their use-by, and peroxide formers open too long
No recorded batch is within 90 days of its use-by, and no peroxide former has been open a year.
Storage that needs a look
Cabinet 1 Gas cylinders belong in a cylinder store, not a cabinet — Helium Canister, ICO 16g threaded CO2 Cartridges, Pro-Power Butane Gas, Swan Gas Lighter Refill
Cabinet 2 Gas cylinders belong in a cylinder store, not a cabinet — Tensospray
Not seen on the last cupboard walk
Every item looked for on a walk was found, or no walk has been recorded yet.
Stores wanting an order
Advance AT7 PVC Electrical Insulation Tape (Brown) 12mm x 33m — 3 held, below the reorder level of 10
Advance AT7 PVC Electrical Insulation Tape (Grey) 12mm x 33m — 8 held, below the reorder level of 10
Advance AT7 PVC Electrical Insulation Tape (Red) 12mm x 33m — 8 held, below the reorder level of 10
Double Sided Tape — 1 held, below the reorder level of 5
Double Sided Tape, half width — 4 held, below the reorder level of 5
MagTape Matt Pro Grade Gaffer Tape (Green) 25mm x 50m — 2 held, below the reorder level of 3
MagTape Matt Pro Grade Gaffer Tape (Orange) 25mm x 50m — 1 held, below the reorder level of 3
MagTape Matt Pro Grade Gaffer Tape (Red) 50mm x 50m — 0 held, below the reorder level of 3 — buy 12 to make it up to 12
Tools out on loan past their due date
Nothing lent out is overdue.
Loans due back this week
Nothing lent out falls due in the next seven days.
Actions open
No corrective actions are open.
Risk assessments waiting for a signature
Nothing sent for approval is waiting to be signed.
Change log review
never reviewed Nobody has recorded reading the change log yet; 1556 entries stand.